Vertiv VS3750 SmartCabinet ID 42U Rack

$16,016.68

Vertiv VS3750 SmartCabinet ID - 42U - 2-Phase 208/230V VAC 60Hz - IP54 Rated - 9in HMI Display - Condenser Not Included - North America The Vertiv SmartCabinet ID VS3750 is a 42U micro data center that offers an all-in-one IT solution...

Choose your options Options and quantity
Secure checkoutEncrypted Shopify payment
Expert guidanceHelp before you order
Shipping detailsDetails vary by product

PRODUCT DETAILS

Everything you need to know.

Vertiv VS3750 SmartCabinet ID - 42U - 2-Phase 208/230V VAC 60Hz - IP54 Rated - 9in HMI Display - Condenser Not Included - North America The Vertiv SmartCabinet ID VS3750 is a 42U micro data center that offers an all-in-one IT solution for harsh environments. With a Zero-U space-saving design, the VS3750 provides a full 42U of rack space for critical IT equipment while offering IP54 protection. Combining scalable IT cooling, power distribution, and emergency power, the Vertiv SmartCabinet ID brings peace of mind to even the toughest of IT applications. Model Number VS3750 Product Name Vertiv VS3750 SmartCabinet ID 42U Rack Product Type Server Cabinet Input Voltage 2-Phase 208/230V VAC 60Hz PMB Input Connector L6-30P Protection Rating IP54 Rated Dimensions W x D x H, mm (in) 800 x 1200 x 2000 (31.5 x 47.2 x 78.7) Weight (Rack & Evaporator), kg (lbs) 300 (661.4) Static Load / Dynamic Load, kg (lbs) 1300 (2866) / 1000 (2204.6) U-Space (Usable) 42U Display Screen 9in HMI Communication Protocols Web, SNMP (v1/v2) Environmental Sensors, std (3) Temp/Humidity sensor, (2) Door sensors, (1) Leak Detection Sensor Noise dB(A) at 2m < 66 (without condensing unit) Controls and Monitoring iCOM Edge Compliance Approval UL Color RAL7021 Overvoltage Category Level 2 Pollution Degree Level 2 Earthing System TT and TN Model ZRC07U Rated Capacity, kW (kBtu/h)* 7 (23.9) Capacity Modulation Range 0 - 100% Nominal Airflow, m3/h (CFM) 1500 (882.9) Coefficient of Performance (COP), W/W 2.9 Sound Pressure (at 2m), dB(A) < 66 Refrigerant Type R410-A Footnote *Net sensible cooling rated at 95F/24%RH Indoor, 95F Outdoor Cabinet Temp, C (F) 0 to 45 (32 to 113) Evaporator Temp, C (F) 18 to 45 (64.4 to 113) Standard Condensing Unit Temp, C (F) -15 to 48 ( 5 to 118) Low Ambient Condensing Unit Temp, C (F) -35 to 48 (-31 to 118) Ambient Storage Temp, C (F) -40 to 70 (-40 to 158) Ambient Humidity For Cabinet: 5% RH to 90% RH (no condensation). For Evaporator: 17% RH to 60% RH. For Storage: 95% RH at 40 C (104 F) Altitude 1000m (3280.8 ft) without derating. Contact Vertiv for derating up to < 3000 m (9842.5 ft). Ingress Protection Rating IP54 / NEMA 3 EMC FCC Part 15 Class A Safety UL 2416 / CSA 60368-1 Transport ISTA 3B AC Condensing Unit Standard condensing unit ZCC07U or Low ambient condensing unit ZCL07U UPS GXT5-10KMVRT6UXLN with POD PD2-103 and RDU101 rPDU Various, depends on UPS solution Features and Benefits Full rack utilization: Zero-U cooling design allows for full rack utilization and more IT deployment per square feet.