In stock SKU: 816

VoltNuvia

Vertiv GXT5-3KL630RT2UXL Liebert UPS Rack Tower L6-30P Input

$1,227.81

Vertiv GXT5-3KL630RT2UXL Liebert UPS Rack Tower L6-30P Input with Optional Vertiv RDU101 Communications Card - 3kVA - 208 V AC - 2U - NEMA L6-15R - NEMA L6-30R Designed for server rooms, network closets, and other distributed IT applications, this GXT5 3KL630RT2UXL...

Choose your options Options and quantity
Secure checkoutEncrypted Shopify payment
Expert guidanceHelp before you order
Shipping detailsDetails vary by product

PRODUCT DETAILS

Everything you need to know.

Vertiv GXT5-3KL630RT2UXL Liebert UPS Rack Tower L6-30P Input with Optional Vertiv RDU101 Communications Card - 3kVA - 208 V AC - 2U - NEMA L6-15R - NEMA L6-30R Designed for server rooms, network closets, and other distributed IT applications, this GXT5 3KL630RT2UXL UPS Rack Tower L6-30P Input from Liebert offers solid power capacity in a small rack/tower convertible form factor. This UPS has an output of 3000VA / 3000W and an input of 208 VAC at 70 Hz, allowing for the two programmable NEMA L6-15R and NEMA L6-30R outlets to reliably distribute power for optimum battery usage. A NEMA L6-30P is the primary input connection of this UPS. Liebert has designed the GTX5 to feature pure sine wave output, a rotatable LCD display panel, a convertible rack/tower design, a hot-swappable internal battery, and output distribution options. This GXT5 UPS sports a recharge time of three hours to 90% and has a runtime of 3 minutes at full-load and 9 minutes at half-load. Remote UPS firmware upgrade and remote management capabilities are possible through the preinstalled RDU101 SNMP/Webcard, so you can view your sensors and tweak settings through a connected network. The addition of intelligent battery health management also optimizes service life and warns you of battery failure, meaning you can remain comfortable that your connected devices are adequately powered. Basic monitoring of the GTX5 and unattended controlled shutdown of your computer in case of a power failure can be done using the Liebert Power Assist software via the USB port. The GTX5 features programmable outlets that can be tweaked to run for a certain amount of time. Normal Mode: When utility power is normal, Normal mode employs the rectifier and inverter to provide voltage and frequency stabilized power to the load. The charger charges the battery in normal mode. On the front panel display, the run-indicator (green) is ON, the alarm indicator is OFF, and the buzzer is silent. Bypass mode supplies power to the load from the bypass source (utility power) if an overload or fault occurs during normal operation. On the front panel display, the run indicator (green) is ON, the alarm indicator (yellow) is ON, and the buzzer beeps once every two seconds. The LCD Flow screen displays On Bypass. Battery Mode: Battery mode supplies battery power to the load if utility power fails or if the utility voltage goes outside of the permissible range. On the front panel display, the run indicator (green) is ON, the alarm indicator (yellow) is ON, and the buzzer beeps once each second. The LCD Flow screen displays On Battery. Eco Mode: The energy-saving ECO mode reduces power consumption by powering the load via bypass if the bypass voltage is normal or by powering the load via the inverter when the bypass voltage is abnormal. You can use ECO mode to power equipment that is not sensitive to power grid quality to via bypass and reduce power consumption. Maintenance Bypass Mode: Used in the unlikely event that the UPS requires maintenance or repair, maintenance bypass mode powers the connected equipment with utility power while electrically isolating the internal UPS components. Model Number GXT5-3KL630RT2UXL Product Name Vertiv GXT5-3KL630RT2UXL Liebert UPS Rack Tower L6-30P Input Product Type UPS Plug/Connector Type NEMA L6-30P Receptacle Type NEMA L6-15R, NEMA L6-30R Receptacle Detail 2 x NEMA L6-15R, 2 x NEMA L6-30R Bypass Switch Automatic & Manual, Internal Emergency Power OFF Yes Cord Length 10 ft. (3.05 m) Transfer Time 0 ns Phase Single Phase Application/Usage Data Center, Mission Critical Equipment Load Capacity (VA) 3kVA Load Capacity (Watt) 3 kW Input Voltage 208 V AC Output Voltage Options 200 V AC, 208 V AC, 220 V AC, 230 V AC, 240 V AC Input Frequency 50 Hz Waveform Type Sine Wave Utility (AC) Mode Overload >200% for 250 ms; 150-200% for 2 s; 125-150% for 10 s; 105-125% for 15 s Status Indicators Full Color Graphic LCD / Diagnostic LEDs: Alarm, Fault Indication Serial Port Yes VGA No Modem (RJ?11) No Network (RJ?45) Yes USB Yes Expansion Slots 1 Battery Characteristics Valve-regulated, Non-spillable Battery Chemistry Lead Acid Backup/Run Time (Full Load) 3 min Backup/Run Time (Half Load) 9 min External Battery Cabinets 1 Backup/Run Time w/ Ext. Cabinet (Full Load) 17 min Backup/Run Time w/ Ext. Cabinet (Half Load) 43.5 min Hot Swappable Yes Environmental Sensors Humidity Sensor, Leak Detection Sensor, Temperature Sensor Rack Height 2U Form Factor Rack/Tower Energy Star Yes Environmentally Friendly Yes Dimensions H 3.35 x W 16.93 x D 21.26 Inches Weight (Approximate) 65.10 lb.